Ultra Micro Spectrometer Series
UM series is built in with the linear CCD type sensor and 8 pin external interface. The optical engine is very simple and optimized for the spectrometer. The optical bench is very rigid and stable for measurement system. The compact size is very flexible for system integration.
Ultra Micro Spectro-module-UM1280 / UM2280
Features
Ultra-compact spectral measurement module; ready to integrate with all kinds of spectral equipment; it is the best choice for embedded spectral measurement applications, even more, in handheld application.
-
High resolution
-
Ultra micro size
-
Affordable price
-
Low implementation costs
* Note - By new optical design that we add cylindrical lens inside, UM2280 provides 3 times higher sensitivity performance than UM1280.
Recommendable Models
Type
Standard
High sensitivity
Wavelength
Range
330~850nm
Slit Size
10μm
25μm
40μm
10μm
25μm
40μm
Resolution
3.5nm
5.5nm
10nm
3.5nm
6nm
10nm
Model
UM1280-V2
UM2280-V2
CCD Type
ILX563A
ILX563A+Cylindrical lens
ILX563A
SNR
150
AD
16
Dark
Noise
65
Stray
Light
0.5%
Specifications
Spectral Resolution
Wavelength Range
Stray Light
Integration time
Fiber Optic Input Connector
Electronic Interface
Weight
Dimensions
3.5~10nm FWHM
330~850nm
0.5%
1ms - user defined
SMA905
CCD I/F directly control through the 8 pins external cable
8g
39.3 (W) x 43.5 (D) x 10.1 (H) mm
Ultra Micro Spectro-module-UM1380/ UM2380/ UM1390/ UM2390
Features
UMX3X0 spectro-module is a new OtO optical platform with 50% footprint
down size compared to UMX2X0 series. Besides the smaller size, the SMA905 is
designed as an optional features. The customer can design the optical detector
head (like collimator or cosine-corrector) to attach to the UMX3X0 to save the
SMA905 space. UMX390 is designed as the right-angled SMA905 type. There is
one micro reflection mirror to change the incident light path. UM1390/ UM2390
provides more flexibility for OEM customer on the product design and integration.
UM Series spectro-module is built in with the linear CCD type sensor and 8
pin external interface.
-
TCD1254 2500-element
-
High resolution
-
Ultra micro size
-
Affordable price
-
Low implementation costs
Recommendable Models
Type
Standard
SMA905
90 deg.
High Sensitivity
SMA905
90 deg. + High Sensitivity
Wavelength
Range
330~850nm
Slit Size
10μm
25μm
40μm
10μm
25μm
40μm
10μm
25μm
40μm
10μm
25μm
40μm
Resolution
3nm
6nm
10nm
3nm
6nm
10nm
3nm
6nm
10nm
3nm
6nm
10nm
Model
UM1380
UM1390
UM2380
UM2390
CCD Type
Toshiba TCD 1254
Toshiba TCD 1254 + Cylindrical Lens
SNR
200
AD
16
Dark
Noise
103
Stray
Light
0.5%
Note UM1380/UM2380 is the standard type spectrometer module. UM1390-V2 & UM2390-V2 is with right-angled SMA905.
Specifications
Spectral Resolution
Wavelength Range
Stray Light
Integration time
Fiber Optic Input Connector
Electronic Interface
Weight
Dimensions
Toshiba TCD1254 Detector
Slit width
3~10nm FWHM
330~850nm
0.5%
1ms - user defined
SMA905
CCD direct control
13g
UM1380/ UM2380 : 23.2 (w) x 31 (D) x 10 (H) mm
UM1390/ UM2390 : 23.2 (w) x 31 (D) x 8.5 (H) mm
Readout Rate : 2MHz
25 /40μm