Owl Series
새로이 출시된 Owl Series 분광기는 다양한 분야에서 응용이 가능한 소형 분광기로 High Resolution, High Sensitivity를 지원합니다.
* OW1070
-
3648 pixel CCD sensor
-
Wavelength range : 835 ~ 955 nm、810 ~ 875 nm、920 ~ 970 nm
-
Best choice for VCSEL, 3D sensing , thin film measurement
-
High-Resolution 0.1~0.2 nm
* OW1080
-
4096 pixel CMOS sensor, high sensitivity, microsecond (μs) measurement
-
Wavelength range : 835 ~ 955 nm、810 ~ 875 nm、920 ~ 970 nm
-
Best choice for VCSEL, 3D sensing , thin film measurement
-
High-Resolution 0.1~0.2 nm
Owl (OW) Series spectrometer, built with the linear CCD/CMOS type sensor and high performance 32bits RISC controller in, is specially designed for high resolution measurement requirement. OW series has outstanding stability of thermo-hydro variation, vibration and shock on resolution and wavelength shift performance.
OW1070/OW1080
Features
-
Responsive wavelength: 835 ~ 955 nm、810 ~ 875 nm、920 ~ 970 nm,
and customizable within range 200-1000 nm. -
Optical resolution: 0.05 to 0.2 nm, depending on the combination of various
slits and gratings -
A variety of sensor can be chosen for specific application:
OW1070: High sensitive CCD linear image sensor (3648 pixel)
OW1080: High sensitivity CMOS linear image sensor (4096 pixel)
Modular configuration with various grating, sensor, and slit options -
Integration times from 420μs ~ 24sec, depending on sensors
-
16 bit, 15MHz A/D Converter
-
USB 2.0 @ 480 Mbps (High speed)
-
8-pin connector for interfacing to external - 6 user programmable digital I/O
-
Plug-n-play interface for PC application
-
Extremely precise continuous multiple exposures, providing up to 4,000
spectra buffering -
Flash ROM storage for
Wavelength Calibration Coefficients
Linearity Correction Coefficients
Intensity Calibration Coefficients
Owl Spectrometer
OW1070
Specifications
SPEC
Sensor
Dark Noise(Upper Limit)
Dynamic Range
SNR
Optical Design
Dimension
Grating
Slit Size
Integration Time
Resolution(FWHM)
Environmental Conditions
Interfaces
Input Fiber Connector
Power
OW1070
3648 pixel CCD
40
2200:1
400
Czerny-Turner Optical Structure 2nd&3rd order rejection
163(L) x 163(W) x 61(H) mm
2 grating options
5μm
4ms~24s
835~955nm : 0.1~0.2nm
810~875nm : <0.1nm
920~970nm : <0.1nm
Storage -30°C to +70°C
Operation -10°C to +50°C
Humidity 0% - 90% non-condensing
Micro USB 2.0 @ 480 Mbps (High speed)
SMA905
Power requirement (USB): 330mA at +5 VDC
DC Jack for TEC: 500mA at +5VDC
Supply voltage: 4.75-5.25
Power-up time : < 4s
Maximum USB input power Vcc : +5.25VDC
Maximum I/O signal voltage : +5.5VDC
Owl Spectrometer
OW1080
Specifications
SPEC
Sensor
Dark Noise(Upper Limit)
Dynamic Range
SNR
Optical Design
Dimension
Grating
Slit Size
Integration Time
Resolution(FWHM)
Environmental Conditions
Interfaces
Input Fiber Connector
Power
OW1080
4096 pixel CCD
50
2200:1
350
Czerny-Turner Optical Structure 2nd&3rd order rejection
163(L) x 163(W) x 61(H) mm
2 grating options
5μm
420μs~24s
835~955nm : 0.1~0.2nm
810~875nm : <0.1nm
920~970nm : <0.1nm
Storage -30°C to +70°C
Operation -10°C to +50°C
Humidity 0% - 90% non-condensing
Micro USB 2.0 @ 480 Mbps (High speed)
SMA905
Power requirement (USB): 330mA at +5 VDC
DC Jack for TEC: 500mA at +5VDC
Supply voltage: 4.75-5.25
Power-up time : < 4s
Maximum USB input power Vcc : +5.25VDC
Maximum I/O signal voltage : +5.5VDC